Back 

MrGreen Certi green soy cleaner/degreaser

Material Safety Data Sheet

OSHA's Hazard Communication Standard

U.S. Department of Labor

29 CFR 1910.1200 OMB No. 1218-0072

Genlabs

Identity # 04901 Name CERTI GREEN SOY DEGREASER

Date Prepared- 6/14/2007

Appearance and Odor- LIGHT AMBER COLOR LIQUID WITH CITRUS ODOR.

pH- N/A

Special Fire Fighting Procedures NONE

Unusual Fire and Explosion Hazards- NONE

Hazardous Polymerization- NONE

Section 1

Manufacturer's Name - Genlabs (Formerly General Chemical Corp.)

Address - 5568 Schaefer Ave. Emergency Phone (Chemtrec) 1-(800)-424-9300

City - Chino State - CA Phone - (909) 591-8451

Contact Person - Solaiman Jonatan

Section 2 -Ingredients/Identity Information

Components CAS# OSHA PEL ACGIH TLV Weight% (Optional)

Section 3 - Physical/Chemical Characteristics

Vapor Pressure - Not Tested

Vapor Density - Not Tested Melting Point - Not Tested

Evaporation Rate - Not Tested

Section 4 - Fire and Explosion Hazard Data

(0- Least, 4- Extreme)

Flammable Limits - Not Tested

Section 5 - Reactivity Data

Stability - Stable

Conditions to Avoid - None

NFPA Hazard Rating - H F R S HMIS Hazard Rating -

1 1 0 0

VOC Content- < 19.6 g/L

Boiling Point- Specific Gravity- 0.980

Solubility In Water- Insoluble

Flash Point- >212 F

LEL- Not Tested

UEL- Not Tested

Extinguishing Media- CO2, DRY FOAM

Incompatible Materials to Avoid- Strong oxidizers, ammonia, chlorine bleach

Conditions to Avoid- None

Hazardous Decomposition or Byproducts- CO, CO2

Note: Contains biodegradable materials.

H

1

F

1

R

0

DOT# NONE

Methyl Ester, Soybean Oil 67784-80-9 N/A N/A

D-Limonene 5989275 NONE NONE

Alcohols, Ethoxylated Proprietary N/A N/A

# 04901

Other Special Requirements NONE

Section 6 - Health Hazard Data

Routes of Entry

Inhalation? - Possible

Skin? - Possible

Ingestion? - Possible

Health Hazards - Same as Signs and Symptoms of Exposures

Note - All Chemicals in this Product are Found on the TSCA Inventory List.

OSHA Carcinogenicity? - None; NTP? - None; IARC Monographs? - None.

Medical Conditions Generally Aggravated by Exposure - Same as Signs and Symptoms of Over Exposure

Emergency and First Aid Procedures

Eyes - Flush With Water For 15 Minutes. If Irritation Persists, Call Physician.

Section 7 - Precautions For Safe Handling and Use.

Steps to be taken in case material is released or spilled - Soak up with inert, absorbent material. Scoop up and

place in a proper waste disposal container.

Waste Disposal Method - Dispose of in accordance with state and local regulations.

Precautions To Be Taken In Handling and Storing - Store in a cool, dry place, out of direct sunlight. Do not freeze,

less than or equal to 32 F, or heat above 110 F.

Other Precautions - Keep out of reach of children. Follow directions on the container for proper use of this product.

Section 8 - Control Measures

Respiratory Protection - Open all doors and windows. "If" there is an exposure, and it is above the TLV or PEL, a

NIOSH approved respirator equipped for the exposure or suitable respiratory protection per 29 CRF 1910.134, is

required.

Ventilation Local Exhaust - If Available Special - None

Mechanical - If Available Other - None

Eyes - Burning Sensation

Work Hygenic Practices - Use common sense and care around chemicals. Never mix chemicals. Consult your

supervisor for other practices. All practices depend on your specific business. Directions for use are normally

found on label which will dictate engineering and control measures.

Skin- Wash Off With Soap & Water, If Irritation Persists, Call Physician

Ingestion- Drink Large Amounts of Water, Call Physician

Inhalation- Not Expected to be a Problem

Skin- Slight Irritation

Ingestion-Nausea

Protective Gloves- Plastic or Rubber, Chemical Resistant

Eye Protection- Glasses, Goggles

Other Protective Clothing or Equipment- NONE

Signs and symptons of over exposure:

Note: Genlabs believes the data set forth are accurate, Genlabs makes no warranty with respects thereto and disclaims all

liability for reliance thereon. Such data are offered solely for consideration, investigation and verification. Also, the data set

forth is for the concentrated finished product. All lab samples are for experimental purposes only and used at the customers

discretion

Inhalation- Not Expected To Be A Problem


Item #buMrGreen04901


Sale price $295.00

WE GLADLY ACCEPT ALL OF YOUR MAJOR CREDIT CARDS ;INCLUDING VISA,MASTERCARD,DISCOVER ,PAYPAL AND AMERICAN EXPRESS.


AND FOR YOUR CONVENIENCE WE WILL PROCESS EMAIL ,FAX AND TELEPHONE ORDERS AS WELL.

EMAIL US AT:N2WINNERCHEMICAL@AOL.COM
FAX: 909-886-9010 
PHONE TOLL FREE: 1-877-597-6261

  Back